Skip to content. Skip to navigation menu.
We are closed between 24th Dec ‘24 at 12 pm until 2nd Jan ‘25. Last Order Deadlines: Small items: 23rd Dec for delivery by 24th Dec. Large items: 19th Dec for delivery by 23rd Dec. Collections must be made from our warehouse before 12 pm on 24th Dec.

PIG® Four-IBC Modular Spill Pallet

PAKE132 Write a Review
Holds (4) 1000 ltr. IBCs, 1382 L Sump Capacity, 16328 kg Load Capacity
Expandable Modular unit minimises IBC storage cost and features low deck height for easier loading.  Read More

PRICING (Based on quantity)

1+
1+
£2,108.00
(Ex. VAT)

Description & Specifications

Expandable Modular unit minimises IBC storage cost and features low deck height for easier loading.

Cut your costs for storing multiple IBC units in compliance with regulations; a PIG® Multi-IBC Modular Spill Pallet provides capacity more economically than individual storage units. Flow-through connections let individual components share sump capacity to help you meet storage regulations. The connectable design also allows an easy-loading 22cm deck height.

  • Includes four 284L pallet sections and one 246L Expansion Tank; connected unit provides 1,382L of total capacity to help you meet secondary containment requirements for four 1,000L IBC units
  • Increase sump capacity by connecting on an individual pallet section or Expansion Tank
  • Includes four pairs of 5.7cm diameter, flow-through Bulkhead Fittings that let you easily connect components; additional Fittings sold separately
  • Includes specially-designed Tool Kit for connecting components
  • Each Tank features a hatch lid for easy access to collected liquid
  • Each heavy-duty pallet section supports 4,082kg UDL and measures 159cm square—accommodates all 1,000L IBC units
  • Each pallet section features 4-way forklift pockets for easy moving, plus anti-slip grates that lift out for easy access to sump
  • Pallet sections and tanks are 100% polyethylene to resist corrosion and most chemicals, including acids, solvents and oils
Dimensions 715cm W x 159cm L x 32cm H
Recycled Content 41% Post-Industrial Recycled Polyethylene
Load Capacity UDL 16328 kg
Sump Capacity 1382 L
Double-Stackable Unit Not Double-Stackable
Drain No Drain
Fork Truck Access No Fork Truck Access
Grates (8) 132cm L x 66cm W Grates
Sold as 1 each
Weight 299.5 kg
New Pig Patent 5,562,047 and other foreign patents
# per Pallet 1
Composition Polyethylene
Capacity (4) 1000 ltr. IBCs
Includes

4 - 159cm L x 159cm W x 22cm H Pallet (PAK672-BK-WOD)

1 - 155cm L x 79cm W x 32cm H Expansion Tank (PAK116-BK)

1 - Tool Kit (PAK117)

4 - Bulkhead Fittings (2/pack) (PAK118)

Reviews

Based on 0 review(s)

Additional Information

  • Chemical Compatibility for PIG LDPE Products
  • Instructions for Expansion Tank Assembly
  • The Control of Pollution (Oil Storage) Regulations (Northern Ireland) 2010
    The Regulations apply to above ground oil storage facilities on industrial, commercial and institutional residential sites. They also extend to companies who refine or distribute oil. The Regulations set minimum design standards for new and existing above ground oil storage facilities, codifying existing good practice to ensure that above ground oil storage facilities are adequately constructed. A key requirement of the Regulations is for the storage container to have a secondary containment system (a bund, which is an outer wall or enclosure designed to contain the contents of an inner tank, or, a drip tray) to ensure that any leaking or spilt oil is contained and does not enter the aquatic environment.
  • The Control of Pollution (Oil Storage)(England) Regulations 2001
    This regulation applies to any container with a storage capacity of over 200 litres, and applies to any industrial, commercial or institutional site, e.g. factories, shops, offices, hotels, schools, public sector buildings and hospitals. All types of oil except waste oil are included. A bund or catchpit has to form a container around the tank capable of holding 110% of the contents of the oil stored or 25% of the total volume, whichever is greater. This is known as secondary containment.
  • The Water Environment (Oil Storage) (Scotland) Regulations 2006
    This regulation applies to any container with a storage capacity of over 200 litres. It affects all premises, including land and mobile plant, as well as private dwellings. "Oil" means any kind of oil and includes petrol, diesel, waste and vegetable and plant oil, but does not include bitumen. The storage container, whether indoors or outdoors, must be situated within a secondary containment system capable of holding 110% of the contents of the oil store or 25% of the total volume (whichever is greater).
  • The Water Resources (Control of Pollution) (Oil Storage) (Wales) Regulations 2016
    The Regulations apply to any kind of oil, including petrol, diesel, kerosene, lubricating oil (both mineral and synthetic), waste oil, vegetable and plant oil, and apply to any kind of container which has a capacity of greater than 200 litres which is being used to store oil above ground, whether inside or outside a building. This includes fixed tanks, intermediate bulk containers (IBCs), drums (oil drums or similar containers used for storing oil) or mobile bowsers. The Regulations will come into force in 3 stages - Tanks installed after 15 March 2016 will have to comply with the Regulations from the date they are installed; Existing tanks at significant risk (i.e. facilities that are located within 10 metres of any surface water or wetland, or 50 metres of a borehole or well), will have to comply within 2 years (i.e. by 15 March 2018); Existing tanks not at significant risk will have to comply within 4 years (i.e. by 15 March 2020). The secondary containment system must contain at least 110% of the maximum contents of the oil container, or at least 25% of the total storage capacity if multiple containers are stored, whichever is the greater.

Disclaimers

Flammables Notice

If using this product with flammable liquids, please consider the regulations that apply to storage and handling of flammable liquids and the safety of this application, specifically flammable vapours, static discharge and heat sources. For further assistance, please call Technical Services.

Poly Pallet - Unloaded Notice

Remove all drums & containers from the pallet before moving.

Assembly Required